APPLICATIONS
- Urban wastewater treatment (inlet/outlet controls)
- Sanitation network
- Industrial effluent treatment
- Surface water monitoring
- Pumping drinking water
DIGITAL TECHNOLOGY
- The measure principle is based on IR nephelometry / 850 nm. The sensor can be calibrated with a formazine standard solution
- The NTU sensor integrates a low-cost optical technology, with a very few maintenance and no consumables.
TECHNICAL CHARACTERISTICS
Measures
Measure principle | Diffusion IR at 90 | ||||||||||||
Measure ranges |
|
||||||||||||
Resolution | 0,01 to 1 NTU – mg/L | ||||||||||||
Accuracy | < 5% of the reading | ||||||||||||
Working temperature | 0 C to + 50 C | ||||||||||||
Measure of temperature | Via CTN | ||||||||||||
Stocking temperature | -10 C to + 60 C |
Sensor
Dimensions | Diameter : 27 mm ; length : 170 mm |
Weight | 300 g(sensor +cable 3meters) |
Material | PVC, DELRIN, Ouartz, PMMA, Polyamide |
Maximum pressure | 5 bars |
Connection | 9 armoured connectors, polyurethanen jacket, bare-wires or waterproof Fisher connector |
Degree of protection | IP68 |